regulator: st-pwm: Convert to get_voltage_sel
authorAxel Lin <axel.lin@ingics.com>
Fri, 21 Mar 2014 23:22:38 +0000 (07:22 +0800)
committerMark Brown <broonie@linaro.org>
Mon, 24 Mar 2014 10:49:10 +0000 (10:49 +0000)
Also remove test for selector in st_pwm_regulator_set_voltage_sel, the checking
is already done in .list_voltage.

Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Lee Jones <lee.jones@linaro.org>
Signed-off-by: Mark Brown <broonie@linaro.org>
drivers/regulator/st-pwm.c

index 6ef569ffd9716cdce3e921a62066396ec9c797be..e367af1c5f9dca664827768fa4cefc16aaf9b2aa 100644 (file)
@@ -39,11 +39,11 @@ struct st_pwm_voltages {
        unsigned int dutycycle;
 };
 
-static int st_pwm_regulator_get_voltage(struct regulator_dev *dev)
+static int st_pwm_regulator_get_voltage_sel(struct regulator_dev *dev)
 {
        struct st_pwm_regulator_data *drvdata = rdev_get_drvdata(dev);
 
-       return drvdata->pdata->duty_cycle_table[drvdata->state].uV;
+       return drvdata->state;
 }
 
 static int st_pwm_regulator_set_voltage_sel(struct regulator_dev *dev,
@@ -53,9 +53,6 @@ static int st_pwm_regulator_set_voltage_sel(struct regulator_dev *dev,
        int dutycycle;
        int ret;
 
-       if (selector >= dev->desc->n_voltages)
-               return -EINVAL;
-
        dutycycle = (ST_PWM_REG_PERIOD / 100) *
                drvdata->pdata->duty_cycle_table[selector].dutycycle;
 
@@ -92,7 +89,7 @@ static int st_pwm_regulator_list_voltage(struct regulator_dev *dev,
 
 static struct regulator_ops st_pwm_regulator_voltage_ops = {
        .set_voltage_sel = st_pwm_regulator_set_voltage_sel,
-       .get_voltage     = st_pwm_regulator_get_voltage,
+       .get_voltage_sel = st_pwm_regulator_get_voltage_sel,
        .list_voltage    = st_pwm_regulator_list_voltage,
        .map_voltage     = regulator_map_voltage_iterate,
 };