@@ -26,7 +26,7 @@ fan control mode).
 Temperatures are measured in degrees Celsius and measurement resolution is 1
 degC for temp1 and 0.5 degC for temp2 and temp3. An alarm is triggered when
 the temperature gets higher than high limit; it stays on until the temperature
-falls below the Hysteresis value.
+falls below the hysteresis value.
 
 Fan rotation speeds are reported in RPM (rotations per minute). An alarm is
 triggered if the rotation speed has dropped below a programmable limit. Fan
@@ -67,9 +67,9 @@ Thermal Cruise mode
 
 If the temperature is in the range defined by:
 
-pwm[1-4]_target    - set target temperature, unit millidegree Celcius
+pwm[1-4]_target    - set target temperature, unit millidegree Celsius
                     (range 0 - 127000)
-pwm[1-4]_tolerance - tolerance, unit millidegree Celcius (range 0 - 15000)
+pwm[1-4]_tolerance - tolerance, unit millidegree Celsius (range 0 - 15000)
 
 there are no changes to fan speed. Once the temperature leaves the interval,
 fan speed increases (temp is higher) or decreases if lower than desired.